Traverse is ready to be deployed in today's datacenters and can easily monitor
core infrastructure such as UPS's, Generators, HVACs and tape libraries. Some of the Datacenter infrastructure that Traverse supports includes:
-
Liebert UPS, Liebert HVAC, Amperion Broadband over PowerLine
-
APC UPS, Omnitronix, Valere DC Generators, ADIC Tape Library
|
Supported Metrics
| |
Liebert UPS
UPS Battery Capacity
UPS Battery Voltage
UPS Battery Current
UPS Battery Temp
UPS Battery Remaining Time
UPS Input Line Over Voltage
UPS Input Line Under Voltage
UPS Output Line Voltage
UPS Input Line Current
UPS Output Line Current
UPS Input Frequency
UPS Output Frequency
UPS BrownOuts
UPS BlackOuts
UPS Output Load
UPS Inverter Status
UPS Alarm Conditions
UPS Bypass Status
Generic UPS
UPS Battery Status
UPS Battery Capacity
UPS Battery Temp
UPS Battery Needs Replacement
UPS Voltage
UPS Output Status
UPS Battery Voltage
UPS Battery Remaining Time
UPS Output Load
UPS Input Voltage
UPS Output Voltage
UPS Input Current
UPS Output Current
APC UPS
APC UPS Battery Status
APC UPS Battery Capacity
APC UPS Battery Temp
APC UPS Battery Needs Replacement
APC UPS I/O Voltage
APC UPS Output Status
Disk Space Utilization (SNMP)
CPU Utilization (SNMP)
Physical Memory Utilization (SNMP)
Virtual Memory Utilization (SNMP)
System Uptime (SNMP)
Network Interface: Availability (SNMP)
Network Interface: Bandwidth Utilization (SNMP)
Network Interface: Packets Transmitted (SNMP)
Network Interface: Traffic Volume (SNMP)
|
APC NetBotz Devices
Sensor Temperature Reading
Sensor Humidity Reading
Sensor Communication Status
Outlet Status
Avocent Intelligent Power Strips
Current Sensor 1
Current Sensor 2
Current Sensor 1
Temperature Sensor 1
Temperature Sensor 2
Temperature Sensor 3
Humidity Sensor 1
Humidity Sensor 2
Humidity Sensor 3
Voltage Sensor 1
Voltage Sensor 2
Voltage Sensor 3
Outlet Status
Amperion
Broadband over PowerLine
Amperion PowerLine Card Status
Amperion AC Line Status
Amperion Regulated Voltage
Amperion Extractor/Injector Gain
Amperion PLC Specific Errors
Amperion Cooling Fan Status
Amperion Digital Board Temperature
Disk Space Utilization (SNMP)
CPU Utilization (SNMP)
Physical Memory Utilization (SNMP)
Virtual Memory Utilization (SNMP)
System Uptime (SNMP) >
Network Interface: Availability (SNMP)
Network Interface: Bandwidth Utilization (SNMP)
Network Interface: Packets Transmitted (SNMP)
Network Interface: Traffic Volume (SNMP)
Omnitronix
Sensor State
Relay/Contact State
Sensor State
Relay/Contact State
Sensor State
Relay/Contact State
Contact Closure Status
|
Liebert HVAC
Number of Conditions
Overall System State
Cooling Sub-system State
Heating Sub-system State
Humidifier Sub-system State
Dehumidifier Sub-system State
Econ-o-cycle Sub-system State
Temperature Probe (High)
Temperature Probe (Low)
Humidity Probe (High)
Humidity Probe (Low)
Valere DC Generators
Valere Power Module Status
System Voltage
System Current
Controller Internal Temperature
Battery Temperature
Printer
Printer Status
Capacity
Status
ADIC Tape Library
Library Global Status
Library Start-Up Status
Drive SCSI State
Mover SCSI State
Mover Pick Retries
Mover Place Retries
Mover Load Retries
Mover Scan Retries
Mover Door Status
Cisco Vtp
Status
Traffic
Err |
|